Basic Info.
Model NO.
IPS-SP48-7.5
Voltage Regulating Mode
/
Power Supplying System
/
Energy Transmission
/
Modulation System
/
Certification
CE
Brand
Idealplusing
Output Voltage
0-48V
Output Current
7.5A
Max Power
360W
OEM
Support
ODM
Support
Size
Customizable
Net Weight
Customizable
Transport Package
Carton
Specification
48V 7.5A 360W
Trademark
IDEALPLUSING
Origin
China
Production Capacity
10000PCS/ Month
Product Description
Mean Well IPS-350 series 12V 24V 36V 48V meanwell single output enclosed type Switching Power Supply
I. FEATURES
1 | Support 0-5vdc / 0-12vdc analog signal external control switching mode 200w 0-200v 0-220v Variable dc power supply |
2 | Adjustable with Compact size, light weight |
3 | Wide range AC Input , AC input 110V/220Vac input selected by switch |
4 | 100% full load burn-in test |
5 | Protection: Short circuit / Over load / Over voltage |
6 | Fixed switching frequency at 25KHz |
7 | 1 year warranty |
8 | High efficiency, reliability quality, competitive cost |
9 | 0-5Vdc / 0-10Vdc External control output (Optional) |
10 | Extra adjustable potentiometer (Optional) |
11 | Output voltage adjustable, output current be fix |
II . COMMON SPECIFICATION
Adjustable range for dc voltage | The output voltage is 100% adjustable through the potentiometer |
AC input voltage range | AC 95-125V 60Hz | AC174-264VAC 50Hz Manual switch |
Input current | 115V/2.11A | 230V/1.06A |
AC in lash current | Cold start current 25A/230V |
leakage current | ≤1.5mA 230V AC |
Overload protection | Load more than 110%~120% switch to constant current mode |
Over-voltage protection | ≥15% of output voltage |
Setup rise hold time | 200ms 100ms 20ms |
Vibration | 10-50Hz, 2G 10 minutes/cycle X, Y, Z axis each 60 minutes |
Withstand voltage | Input to shell 1500V/3mA AC | Input to output 1500V/3mA AC | Input to output 500V/3mA AC |
working temperature | -10ºC-65ºC,20%-90%RH |
Storage temperature | -10ºC--65ºC,20%--95%RH |
Net weight | 0.8KG |
Dimension | 200L*98W*42H(MM) |
OTHERS | |
Output voltage tolerance | 1% |
Wave and noise | 150mV P-P |
Efficiency | 91% |
III . MODEL INFOMRATION
MODEL | IPS-SP | IPS-SP3.3-60 | IPS-SP4.2-60 | IPS-SP5-60 | IPS-SP12-29 | IPS-SP15-23.2 | IPS-SP24-14.6 | IPS-SP36-9.7 | IPS-SP48-7.3 | |||||
Output | DC voltage | 3.3V | 4.2V | 5V | 12V | 15V | 24V | 36V | 48V | |||||
RATED current | 60A | 60A | 60A | 29A | 23.2A | 14.6A | 9.7A | 7.3A | ||||||
Current Rated | 0-60A | 0-60A | 0-60A | 0-29A | 0-23.2A | 0-14.6A | 0-97A | 0-7.3A | ||||||
Rated power | 198W | 252W | 300W | 348W | 348W | 350.4W | 349.2W | 350.4W | ||||||
Ripple&Nosie(max)Note.2 | 150mVp-P | 150mVp-P | 150mVp-P | 150mVp-P | 150mVp-P | 150mVp-P | 200mVp-P | 200mVp-P | ||||||
Voltage adj,Range | 2.97-3.6V | 3.6-4.4V | 4.5-5.5V | 10.2-13.8V | 13.5-18V | 21.6-28.8V | 32.4V-39.6V | 43.2-52.8V | ||||||
VOLTAGE TOLERANCE Note. 3 | ±4.0% | ±4.0% | ±3.0% | ±1.5% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||||
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||||||
LOAD REGULATION Note .5 | ±2.5% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ||||||
SETUP RISE TIME | 1500ms . 50ms / 230VAC 1500ms . 50ms / 115VAC at full load | |||||||||||||
HOLD UP TIME ( Typ . | 16ms / 230VAC 12ms / 115VAC at full load | |||||||||||||
INPUT | Voltage range | 90-132VAC /180-264VAC by switch 240VDC~370VDC(switch on 230VAC) | ||||||||||||
Frequency range | 47~63Hz | |||||||||||||
Efficiency (typical) | 79.5% | 81.5% | 83.5% | 85% | 86% | 88% | 88.5% | 89% | ||||||
Ac current(Typ.) | 6.8A/115VAC 3.4A/230VAC | |||||||||||||
INRUSH CURRENT(TyP.) | 60A/115VAC 60A/230VAC | |||||||||||||
LEAKAGE CURRENT(TyP.) | < 2mA / 240VAC | |||||||||||||
PROTECTIO | OVER LOAD | 110-140% rated output power | ||||||||||||
Protection type Hiccup mode, recovers automatically after fault condition is removed | ||||||||||||||
OVER VOLTAGE | Protection type: Shut down olp voltage, re-power on to recover | |||||||||||||
3.8-4.45V | 4.6-5.4V | 5.75-6.75V | 13.8-16.2V | 18-21V | 28.8-33.6V | 41.4-46.8V | 55.2-64.8V | |||||||
OVER TEMPERATURE | Hiccup mode, recovers automatically after fault condition is removed | |||||||||||||
FUNCTION | FAN ON/OFF CONTROL(Typ. | RTH3≥50ºC FAN ON,≤40ºC FAN OFF | ||||||||||||
ENVIRONMENT | WORKING TEMP | -30-+70C( Refer to "Derating Curve") | ||||||||||||
WORKING HUMIDITY | 20-90% RH non-condensing | |||||||||||||
STORAGE TEMP. HUMIDITY | -40~+85ºC. 10~95%RH | |||||||||||||
STORAGE TEMP. HUMIDITY | 40~+85ºC,10~95%RH | |||||||||||||
TEMP. COEFFICIENT | ±0.03%/ºC(0-50ºC) | |||||||||||||
VIBRATION | 0-500HZ, 5G 10min /cycle, 60min. each along X, Y, Z axes | |||||||||||||
SAFETY | SAFETY STANDARDS | UL60950-1 approved | ||||||||||||
WITHSTAND VOLTAGE | 1/P-O/P. 3KVAC I/P-FG: 2KVAC O/P-FG: 0.5KVAC | |||||||||||||
ISOLATION RESISTANCE | V/P-O/P LP-FG O/- FG: 100M Chms/500VDC /25C/70%RH | |||||||||||||
OTHERS | MTBF | 327 9K hrs min . MIL-HDBK-217F ( 25 C ) | ||||||||||||
DIMENSION | 215*115*30MM(L*W*H) | |||||||||||||
PACKING | ||||||||||||||
NOTE | 1 . All parameters NOT specally menod are measured a 230VAC nu ed ad and 25 of ament temperature2 Rple & nose are measure a 0MHZ of bawh g a 1w w m wh a 4 l acor3 . Tolerance incudes set up tolerance , line regulation and load regulation .Line regulation is measured from low line to high line at rated load5 . Load regulation is measured fromm % to 1000% rated load6 . Length of set u time is measured at old st a T N OFF he power supply very quicky may lead to increase of the set up7 . The 150 % peak oad capab s i i for o s for 12-48 5 w n r h p mode if the peak load s deliveredfor over 1 second and will recover once ites to the rated current level ( 1 15VAC / 230VAC )8 . The ambient meare dea of 5 / 1000 is ded or oea aude greater han 2000m ( 6500ft |