Basic Info.
Model NO.
SCN-1200-12
Voltage Regulating Mode
Frequency Modulation Type
Power Supplying System
Terminal Power Distribution Equipment
Energy Transmission
Two-way Transmission
Modulation System
PFAW
Certification
CE, RoHS
Brand
Weho
Hold up Time
30ms/230VAC 12ms/115VAC at Full Load
Voltage Range
85 ~ 264VAC 120 ~ 373VDC
Frequency Range
47~63Hz
Efficiency
89%
Leakage Current
<0.75mA / 240VAC
Transport Package
Carton or Plywood Case
Specification
291mm*132mm*98mm
Trademark
Weho
Origin
Zhejiang
Production Capacity
50000/Year
Product Description
Switching Power Supply CE Rohs Din Rail Smps SCN-1200-12 1200w 12v 100a power supply
Features:
1.Full range AC 85-264V Input
2. Protections: Short circuit / Overload / Over voltage / Over temperature
3. 100% full load burn-in test
4. Low cost, high reliability
5. 24 months warranty
Model | SCN-1200-12 | SCN-1200-24 | SCN-1200-36 | SCN-1200-48 |
DC output voltage | 12V 0~100A | 24V 0~50A | 36V 0~33A | 48V 0~25A |
Wave and noise | 120mVp-p | 200mVp-p | 200mVp-p | 240mVp-p |
Inlet wire stabilily | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Efficiency | 80% | 85% | 85% | 87% |
Adjustable range for DC voltage | ±10% | ±10% | ±10% | ±10% |
Input voltage range | 90~132VAC/180~264VAC by switch 254~370VDC 47~63Hz | |||
Impact current | Cold start current 45A/230VAC | |||
Overload protection | 105% -135% cut off the output, automatic recovery | |||
Over voltage protection | 115%-140% shut down O/P voltage, re-power on to recover | |||
Setup, rise, hold up time | 2000ms, 50ms, 20ms/230VAC at full load | |||
Withstand voltage | I/P-O/P: 1.5kV I/P-FG: 1.5kV OP-FG: 0.5kV 1 minute | |||
Isolation resistance | I/P-O/P I/P-FG O/P-FG: 500VDC/100MΩ | |||
Working temperature | -10ºC~+50ºC | |||
Dimension | 291 x 132 x 136mm | |||
Weight | 5.3kg | |||
Packing | 38 x 37.5 x 21CM/2PCS/11kg |