Basic Info.
Model NO.
S-60
Voltage Regulating Mode
Frequency Modulation Type
Power Supplying System
Terminal Power Distribution Equipment
Energy Transmission
Two-way Transmission
Modulation System
PFAW
Certification
CE, RoHS
Brand
Weho
Hold up Time
30ms/230VAC 12ms/115VAC at Full Load
Voltage Range
85 ~ 264VAC 120 ~ 373VDC
Frequency Range
47~63Hz
Efficiency
89%
Leakage Current
<0.75mA / 240VAC
Transport Package
Carton or Plywood Case
Specification
99mm*82mm*30mm
Trademark
Weho
Origin
Zhejiang
Production Capacity
50000/Year
Product Description
S-60-12 power supply 220vac to 12vdc power switching 12v 5a power supplies
Features:
1.Full range AC 85-264V Input
2. Protections: Short circuit / Overload / Over voltage / Over temperature
3. 100% full load burn-in test
4. Low cost, high reliability
5. 24 months warranty
Model | S-60-5 | S-60-12 | S-60-15 | S-60-24 | S-60-48 |
DC output voltage,current | 5V 0~12A | 12V 0~5A | 15V 0~4A | 24V 0~2.5A | 48V 0~1.25A |
Wave and noise | 75mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 200mVp-p |
Inlet wire stabilily | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Efficiency | 72% | 78% | 79% | 82% | 82% |
Adjustable range for DC voltage | ±10% | ±10% | ±10% | ±10% | ±10% |
Input voltage range | 90~132VAC/180~264VAC by switch 254~370VDC 47~63Hz | ||||
Impact current | Cold start current 15A/115VAC 30A/230VAC | ||||
Overload protection | 105% -150% cut off the output, automatic recovery | ||||
Over voltage protection | |||||
Setup, rise, hold up time | 200ms, 100ms, 20ms/230VAC at full load | ||||
Withstand voltage | I/P-O/P: 1.5kV I/P-FG: 1.5kV OP-FG: 0.5kV 1 minute | ||||
Isolation resistance | I/P-O/P I/P-FG O/P-FG: 500VDC/100MΩ | ||||
Working temperature | -10ºC~+50ºC | ||||
Dimension | 159 x 98 x 38 mm | ||||
Weight | 0.5kg | ||||
Packing | 34 x 32 x 24CM/30PCS/15kg |