Basic Info.
Model NO.
HDR
Input Voltage
85~264VAC 120~373VDC
Connection Mode
Series Switching Power Supply
Starting Mode
Separate-excited Switching Power Supply
Voltage Regulating Mode
Width Modulation Type
Power Supplying System
Terminal Power Distribution Equipment
Energy Transmission
One-way Transmission
Modulation System
PWM
Certification
CE, RoHS, CCC, FCC
Payment
Paypal\Tt\Western Union\Trade Assurance
Protections
Short Circuit Overtemp Overload Overvolt
Size
35*90*54.5mm
Output Current
1.5A
Product Name
Hdr
Weight
0.13kg
MOQ
1PCS
Type
AC DC
Efficiency
85%-90%
Output Voltage
24V
Application
Industrial Automation
Transport Package
Safety Packaging
Trademark
NVVV
Origin
Zhejiang, China
Production Capacity
10000 Piece/Pieces Per Month
Product Description
15W Ultra Slim Step Shape DlN Rail HDR - 15 series | ||||||||
SPEClFlCATlON | ||||||||
MODEL | HDR-15-5 | HDR-15-12 | HDR-15-15 | HDR-15-24 | HDR-15-48 | |||
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 48V | ||
RATED CURRENT | 2.4A | 1.25A | 1A | 0.63A | 0.32A | |||
CURRENT RANGE | 0 ~ 2.4A | 0 ~ 1.25A | 0 ~ 1A | 0 ~ 0.63A | 0 ~ 0.32A | |||
RATED POWER | 12W | 15W | 15W | 15.2W | 15.4W | |||
RlPPLE & NOlSE(max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | |||
VOLTAGE ADJ. RANGE | 4.5 ~ 5.5V | 10.8 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 29V | 43.2 ~ 55.2V | |||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
LlNE REGULATlON | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
LOAD REGULATlON | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||
SETUP, RlSETlME | 2000ms, 80ms/230VAC 2000ms, 80ms/115VAC at full load | |||||||
HOLD UP TlME(TYP.) | 30ms/230VAC 12ms/115VAC at full load | |||||||
lNPUT | VOLTAGE RANGE | 85 ~ 264VAC(277VAC operational ) 120 ~ 370VDC(390VDC operational ) | ||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
EFFlClENCY(TYP.) | 80% | 85% | 85.5% | 86% | 87% | |||
AC CURRENT(TYP.) | 0.5A/115VAC 0.25A/230VAC | |||||||
lNRUSH CURRENT(TYP.) | COLD START 25A/115VAC 45A/230VAC | |||||||
PROTECTlON | OVERLOAD | 110 ~ 145% rated output power | ||||||
Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed | ||||||||
OVER VOLTAGE | 5.75 ~ 6.75V | 14.2 ~ 16.2V | 18.8 ~ 22.5V | 30 ~ 36V | 56.5 ~ 64.8V | |||
Protection type : Shut offo/p voltage, clamping by zener diode | ||||||||
ENVlRONMENT | WORklNG TEMP. | -30 ~ +70ºC(Refer to "Derating Curve") | ||||||
WORklNG HUMlDlTY | 20 ~ 90% RH non-condensing | |||||||
STORAGE TEMP., HUMlDlTY | -40 ~ +85ºC, 10 ~ 95% RH non-condensing | |||||||
TEMP. COEFFlClENT | ±0.03%/ºC(0 ~ 50ºC)RH non-condensing | |||||||
VlBRATlON | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along x,Y, Z axes; Mounting: Compliance to lEC60068-2-6 | |||||||
OPERATlNG ALTlTUDE | 2000 meters | |||||||
OVER VOLTAGE CATEGORY | ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters | |||||||
SAFETY | WlTHSTAND VOLTAGE | l/P-O/P:4kVAC | ||||||
lSOLATlON RESlSTANCE | l/P-O/P:100M Ohms / 500VDC / 25ºC/ 70% RH | |||||||
OTHERS | MTBF | 3724.3k hrs min. Telcordia SR-332(Bellcore); 1166.1k hrs min. MlL-HDBk-217F(25ºC) | ||||||
DlMENSlON | 17.5*90*54.5mm(W*H*D) | |||||||
PACklNG | 74g;160pcs/12.9kg/1.09CUFT | |||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The ambient temperature derating of 3.5ºC/1000m with fanless models and of 5ºC/1000m with fan models for operating altitude higher than 2000m(6500ft). |
60W Ultra Slim Step Shape DlN Rail HDR-60 series | |||||||||
SPEClFlCATlON | |||||||||
MODEL | HDR-60-5 | HDR-60-12 | HDR-60-15 | HDR-60-24 | HDR-60-48 | ||||
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 48V | |||
RATED CURRENT | 6.5A | 4.5A | 4A | 2.5A | 1.25A | ||||
CURRENT RANGE | 0 ~ 6.5A | 0 ~ 4.5A | 0 ~ 4A | 0 ~ 2.5A | 0 ~ 1.25A | ||||
RATED POWER | 32.5W | 54W | 60W | 60W | 60W | ||||
RlPPLE & NOlSE(max.) Note.2 | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | ||||
VOLTAGE ADJ. RANGE | 5.0 ~ 5.5V | 10.8 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 29V | 43.2 ~ 55.2V | ||||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||
LlNE REGULATlON | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||
LOAD REGULATlON | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||
SETUP, RlSETlME | 500ms, 50ms/230VAC 500ms, 50ms/115VAC at full load | ||||||||
HOLD UP TlME(TYP.) | 30ms/230VAC 12ms/115VAC at full load | ||||||||
lNPUT | VOLTAGE RANGE | 85 ~ 264VAC(277VAC operational ) 120 ~ 370VDC(390VDC operational ) | |||||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||||
EFFlClENCY(TYP.) | 85% | 88% | 89% | 90% | 91% | ||||
AC CURRENT(TYP.) | 1.2A/115VAC 0.8A/230VAC | ||||||||
lNRUSH CURRENT(TYP.) | COLD START 30A/115VAC 60A/230VAC | ||||||||
PROTECTlON | OVERLOAD | 105 ~ 160% rated output power | |||||||
Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed | |||||||||
OVER VOLTAGE | 5.75 ~ 6.75V | 14.2 ~ 16.2V | 18.8 ~ 22.5V | 30 ~ 36V | 56.5 ~ 64.8V | ||||
Protection type : Shutdown o/p voltage, re-power on to recover | |||||||||
ENVlRONMENT | WORklNG TEMP. | -30 ~ +70ºC (Refer to "Derating Curve") | |||||||
WORklNG HUMlDlTY | 20 ~ 90% RH non-condensing | ||||||||
STORAGE TEMP., HUMlDlTY | -40 ~ +85ºC , 10 ~ 95% RH non-condensing | ||||||||
TEMP. COEFFlClENT | ±0.03%/ºC (0 ~ 50ºC )RH non-condensing | ||||||||
VlBRATlON | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along x,Y, Z axes; Mounting: Compliance to lEC60068-2-6 | ||||||||
OPERATlNG ALTlTUDE | 2000 meters | ||||||||
OVER VOLTAGE CATEGORY | ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters | ||||||||
SAFETY | WlTHSTAND VOLTAGE | l/P-O/P:4kVAC | |||||||
lSOLATlON RESlSTANCE | l/P-O/P:100M Ohms / 500VDC / 25ºC / 70% RH | ||||||||
OTHERS | MTBF | 3524.8k hrs min. Telcordia SR-332(Bellcore); 927.6k hrs min. MlL-HDBk-217F(25ºC ) | |||||||
DlMENSlON | 52.5*90*54.5mm(W*H*D) | ||||||||
PACklNG | 190g;60pcs/13kg/0.91CUFT | ||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The ambient temperature derating of 3.5ºC/1000m with fanless models and of 5ºC/1000m with fan models for operating altitude higher than 2000m(6500ft). |
85 ~ 100W Ultra Slim Step Shape DlN Rail HDR - 100 series | ||||||||
SPEClFlCATlON | ||||||||
MODEL | HDR-100-12 | HDR-100-15 | HDR-100-24 | HDR-100-48 | ||||
OUTPUT | DC VOLTAGE | 12V | 15V | 24V | 48V | |||
RATED CURRENT | 7.1A | 6.13A | 3.83A | 1.92A | ||||
CURRENT RANGE | 0 ~ 7.1A | 0 ~ 6.13A | 0 ~ 3.83A | 0 ~1.92A | ||||
RATED POWER | 85.2W | 92W | 92W | 92.2W | ||||
RlPPLE & NOlSE(max.) Note.2 | 120mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | ||||
VOLTAGE ADJ.RANGE | 12 ~ 13V | 15 ~ 17V | 24 ~ 25.5V | 48 ~ 48.7V | ||||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ||||
LlNE REGULATlON | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||
LOAD REGULATlON | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||
SETUP,RlSETlME | 500ms, 60ms/230VAC 500ms, 60ms/115VAC at full load | |||||||
HOLD UP TlME(TYP.) | 30ms/230VAC 12ms/115VAC at full load | |||||||
lNPUT | VOLTAGE RANGE | 85 ~ 264VAC(277VAC operational ) 120 ~ 370VDC(390VDC operational ) | ||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||
EFFlClENCY(TYP.) | 88% | 89% | 90% | 90% | ||||
AC CURRENT(TYP.) | 3A/115VAC 1.6A/230VAC | |||||||
lNRUSH CURRENT(TYP.) | COLD START 35A/115VAC 70A/230VAC | |||||||
PROTECTlON | OVERLOAD | HDR-100 : 102 ~ 110% rated output power ; HDR-100-XXN : 105 ~ 150% rated output power | ||||||
Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed | ||||||||
OVER VOLTAGE | 14.2 ~ 16.2V | 18.8 ~ 22.5V | 30 ~ 36V | 56.5 ~ 64.8V | ||||
Protection type : Shutdown o/p voltage, re-power on to recover | ||||||||
ENVlRONMENT | WORklNG TEMP. | -30 ~ +70ºC(Refer to "Derating Curve") | ||||||
WORklNG HUMlDlTY | 20 ~ 90% RH non-condensing | |||||||
STORAGE TEMP.,HUMlDlTY | -40 ~ +85ºC, 10 ~ 95% RH non-condensing | |||||||
TEMP. COEFFlClENT | ±0.03%/ºC(0 ~ 50ºC)RH non-condensing | |||||||
VlBRATlON | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along x,Y, Z aXes; Mounting: Compliance to lEC60068-2-6 | |||||||
OPERATlNG ALTlTUDE | 2000 meters | |||||||
OVER VOLTAGE CATEGORY | ; According to EN61558, EN50178,EN60664-1, EN62477-1; altitude up to 2000 meters | |||||||
SAFETY | WlTHSTAND VOLTAGE | l/P-O/P:4kVAC | ||||||
lSOLATlON RESlSTANCE | l/P-O/P:100M Ohms / 500VDC / 25ºC/ 70% RH | |||||||
OTHERS | MTBF | 3271.9k hrs min. Telcordia SR-332(Bellcore); 856.5k hrs min. MlL-HDBk-217F(25ºC) | ||||||
DlMENSlON | 70*90*54.5mm(W*H*D) | |||||||
PACklNG | 0.27kg; 48pcs/13.74kg/0.96CUFT | |||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Harmonic current test at 90% load for HDR-100-XXN. 5. The ambient temperature derating of 3.5ºC/1000m with fanless models and of 5ºC/1000m with fan models for operating altitude higher than 2000m(6500ft). |
150W Ultra Slim Step Shape DIN Rail HDR - 1 5 0 series | ||||||||||
SPECIFICATION | ||||||||||
MODEL | HDR-150-12 | HDR-150-15 | HDR-150-24 | HDR-150-48 | ||||||
INPUT | DC VOLTAGE | 12V | 15V | 24V | 48V | |||||
RATED CURRENT | 115VAC | 10.2A | 8.55A | 5.31A | 2.72A | |||||
230VAC | 11.3A | 9.5A | 6.25A | 3.2A | ||||||
RATED POWER | 115VAC | 122.4W | 128.3W | 127.4W | 130.6W | |||||
230VAC | 135.6W | 142.5W | 150W | 153.6W | ||||||
RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | ||||||
OUTPUT | VOLTAGE ADJ. RANGE | 10.8~ 13.8V | 13.5 ~ 18V | 21.6 ~ 29V | 43.2 ~ 55.2V | |||||
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ||||||
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||||
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ||||||
SETUP, RISE TIME | 500ms, 60ms/230VAC 500ms, 60ms/115VAC at full load | |||||||||
HOLD UP TIME (Typ.) | 30ms/230VAC 12ms/115VAC at full load | |||||||||
INPUT | VOLTAGE RANGE | 85 ~ 264VAC (277VAC operational ) 120 ~ 370VDC (390VDC operational ) | ||||||||
FREQUENCY RANGE | 47 ~ 63Hz | |||||||||
EFFICIENCY (Typ.) | 89% | 89.5% | 90.5% | 90.5% | ||||||
AC CURRENT (Typ.) | 3A/115VAC 1.6A/230VAC | |||||||||
INRUSH CURRENT (Typ.) | COLD START 35A/115VAC 70A/230VAC | |||||||||
PROTECTION | OVERLOAD | 105 ~ 135% rated output power | ||||||||
Hiccup mode when output voltage <50%, recovers automatically after fault condition is removed Constant current limiting within 50% ~100% rated output voltage, recovers automatically after fault condition is removed | ||||||||||
OVER VOLTAGE | 14.2 ~ 16.2V | 18.8 ~ 22.5V | 30 ~ 36V | 56.5 ~ 64.8V | ||||||
Protection type : Shutdown o/p voltage, re-power on to recover | ||||||||||
ENVIRONMENT | WORKING TEMP. | -30 ~ +70ºC (Refer to "Derating Curve") | ||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85ºC, 10 ~ 95% RH non-condensing | |||||||||
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 45ºC) RH non-condensing | |||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X,Y, Z axes; Mounting: Compliance to IEC60068-2-6 | |||||||||
OPERATING ALTITUDE | 2000 meters (Note 4 ) | |||||||||
OVER VOLTAGE CATEGORY | ;According to EN62368 ,EN61558 , EN50178 ,EN60664- 1 , EN62477- 1;altitude up to 2000 meters | |||||||||
SAFETY STANDARDS | IEC62368-1, UL62368-1, UL61010, TUV BS EN/EN61558-2-16, BS EN/EN61558-1, EACTPTC 004 approved; Design refer to BS EN/EN50178, TUV BS EN/EN62368-1 | |||||||||
SAFETY | WITHSTAND VOLTAGE | I/P-O/P:4KVAC | ||||||||
ISOLATION RESISTANCE | I/P-O/P:100M Ohms / 500VDC / 25ºC/ 70% RH | |||||||||
OTHERS | MTBF | 3046.3K hrs min. Telcordia SR-332 (Bellcore) ; 535.9K hrs min. MIL-HDBK-217F (25ºC) | ||||||||
DIMENSION | 105*90*54.5mm (W*H*D) | |||||||||
PACKING | 0.31Kg; 32pcs/11Kg/1.0CUFT | |||||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The ambient temperature derating of 3.5ºC/1000m with fanless models and of 5ºC/1000m with fan models for operating altitude higher than 2000 (6500ft). 5. when the input voltage is 230VAC,delivers EMl Class B for radiated emission for the power supply; when the input voltage is 110VAC, delivers EMl Class A for radiated emission for the power supply. 6. Harmonic current test at 70% load . |
Safety Packaging
1. who are we?
We are based in Zhejiang, China, start from 2015,sell to Domestic Market(30.00%),North America(20.00%),South Asia(6.00%),Mid East(6.00%),Eastern Asia(5.00%),Oceania(5.00%),Southern Europe(5.00%),Western Europe(4.00%),Northern Europe(4.00%),Africa(4.00%),South America(3.00%),Central America(3.00%),Southeast Asia(3.00%),Eastern Europe(2.00%). There are total about 51-100 people in our office.
2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3.what can you buy from us?
Switching power supply
4. why should you buy from us not from other suppliers?
Junlin switching power supply is widely used in industrial automation LED lighting and display, medical, security, power control, metallurgy, water treatment, infrastructure, and other fields.
5. what services can we provide?
Accepted Delivery Terms: null
Accepted Payment Currency:null;
Accepted Payment Type: null;
Language Spoken:null
We are based in Zhejiang, China, start from 2015,sell to Domestic Market(30.00%),North America(20.00%),South Asia(6.00%),Mid East(6.00%),Eastern Asia(5.00%),Oceania(5.00%),Southern Europe(5.00%),Western Europe(4.00%),Northern Europe(4.00%),Africa(4.00%),South America(3.00%),Central America(3.00%),Southeast Asia(3.00%),Eastern Europe(2.00%). There are total about 51-100 people in our office.
2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3.what can you buy from us?
Switching power supply
4. why should you buy from us not from other suppliers?
Junlin switching power supply is widely used in industrial automation LED lighting and display, medical, security, power control, metallurgy, water treatment, infrastructure, and other fields.
5. what services can we provide?
Accepted Delivery Terms: null
Accepted Payment Currency:null;
Accepted Payment Type: null;
Language Spoken:null