Basic Info.
Model NO.
SD-200C-5
Voltage Regulating Mode
Frequency Modulation Type
Power Supplying System
Terminal Power Distribution Equipment
Energy Transmission
Two-way Transmission
Modulation System
PWM
Certification
CE, RoHS, ISO, CCC
Brand
Leyu
Color
Slivery
Weight
1.1kg
Efficiency
84%
MOQ
1 PC
Packing
12PCS/14.4kg/0.92cuft
Protections
Short Circuit /Overload /Over Voltage
Transport Package
Carton
Specification
215*115*50mm (L*W*H)
Trademark
LEYU
Origin
China Mainland
HS Code
8504401990
Production Capacity
3000/M
Product Description
200W Single Output DC-DC Converter SD-200 series
Features:
2:1 wide input range
Protections: Short circuit / Overload / Over voltage / Over temperature
1500VAC I/O isolation
Cooling by free air convection
100% full load burn-in test
24V and 48V input voltage design refer to LVD
2 years warranty
Features:
2:1 wide input range
Protections: Short circuit / Overload / Over voltage / Over temperature
1500VAC I/O isolation
Cooling by free air convection
100% full load burn-in test
24V and 48V input voltage design refer to LVD
2 years warranty
SPECIFICATION | ||||||||
OUTPUT | ||||||||
Model | SD-200B | SD-200C | ||||||
DC Voltage | 5V | 12V | 24V | 48V | 5V | 12V | 24V | 48V |
Rated Current | 34A | 16.7A | 8.4A | 4.2A | 40A | 16.7A | 8.4A | 4.2A |
Current Range | 0~34A | 0~16.7A | 0~8.4A | 0~4.2A | 0~40A | 0~16.7A | 0~8.4A | 0~4.2A |
Rated Power | 170W | 200.4W | 201.6W | 201.6W | 200W | 200.4W | 201.6W | 201.6W |
Ripple & Noise | 100mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 100mVp-p | 120mVp-p | 150mVp-p | 200mVp-p |
Voltage Adj. Range | 4.5 ~ 5.5VDC | 11 ~ 16VDC | 23 ~ 30VDC | 43 ~ 53VDC | 4.5 ~ 5.5VDC | 11 ~ 16VDC | 23 ~ 30VDC | 43 ~ 53VDC |
Voltage Tolerance | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load Regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Setup, Rise Time | 300ms, 50ms at full load | |||||||
INPUT | ||||||||
Voltage Range | B:19 ~ 36VDC C:36 ~ 72VDC D:72 ~144VDC | |||||||
Efficiency | 79% | 82% | 85% | 86% | 81% | 84% | 86% | 86% |
DC Current | 10.8A/24V | 10.6A/24V | 10.4A/24V | 10.4A/24V | 5.4A/48V | 5.2A/48V | 6.7A/48V | 5A/48V |
Inrush Current | C:45A/48VDC D:45A/96VDC | |||||||
PROTECTION | ||||||||
Over Load | 105 ~ 135% rated output power | |||||||
Protection type: Shut down o/p voltage, re-power on to recover | ||||||||
Over Voltage | 5.75 ~ 6.75V | 16.8 ~ 20V | 31.5 ~ 37.5V | 53 ~ 65V | 5.75 ~ 6.75V | 16.8 ~ 20V | 31.5 ~ 37.5V | 53 ~ 65V |
Protection type: Shut down o/p voltage, re-power on to recover | ||||||||
Over Temperature | 95ºC±5ºC(100ºC±5ºC for SD-200B-12 only) TSW1 detect on main power transistor | |||||||
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down | ||||||||
ENVIRONMENT | ||||||||
Working Temp. | -20 ~ +60ºC(Refer to "Derating Curve") | |||||||
Working Humidity | 20 ~ 90% RH non-condensing | |||||||
Storage Temp., Humidity | -40 ~ +85ºC, 10 ~ 95% RH | |||||||
Temp. Coefficient | ±0.03%/ºC (0 ~ 50ºC) | |||||||
Vibration | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |||||||
SAFETY & EMC | ||||||||
Safety Standards | UL60950-1approved (for SD-200C-24 type only), IEC60950-1 CB approved by TUV (for D type only) | |||||||
Withstand Voltage | I/P-O/P: 1.5KVAC I/P-FG: 2.0KVAC O/P-FG: 0.5KVAC | |||||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC / 70% RH | |||||||
EMC Emission | Compliance to EN55022 (CISPR22) Class B | |||||||
EMC Immunity | Compliance to EN61000-4-2,3,4,6,8, light industry level, criteria A | |||||||
OTHERS | ||||||||
Dimension | 215*115*50mm (L*W*H) | |||||||
Weight | 1.1Kg | |||||||
Packing | 12pcs/14.4Kg/0.92CUFT | |||||||
NOTE | ||||||||
1. All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |