Basic Info.
Model NO.
ep3000pro
DC Input
12V/24V/48VDC
AC Input Range
155-265VAC
Capacity
1000W-6000W
Generator Compatible
Yes
Buit in Battery Charger
Yes
Phase
Single
Power Source
Electric Power
Brand
Must/ OEM
Transport Package
Carton
Specification
CE ISO9001
Trademark
MUST
Origin
Original
HS Code
8504403090
Production Capacity
5000per/Month
Product Description
PV3000MPK series pure sine wave inverter
Applied in the field of industrial process controls, battery charging requirements, personal computers, telecommunications, graphics displays, plating and gold recovery industries and wherever required in the commercial, telecoms, mining or industrial markets. Commercial Solar, Recreational Vehicles, Mobile Office, Industrial Wind, Boats, Truck, & RV Residential Solar, Emergency Vehicles, Residential Wind, Fleet & Utility Vehicles, Camping & Outdoors, Renewable Newsletter, Soft start capability for starting heavy loads
New power factor corrected (PFC) charging
Available in 1000 and 3000 watt models Utility grade, sine wave power
Durable construction for long life under extreme environmental conditions
70 AMP automatic three-stage battery charger (bulk, absorption, and float)
Battery equalization with remote temperature sensor for increased performance
Low idle current (less than 1 watt) conserves energy when no loads are present
Built-in starting control circuits for two- and three-wire generator starting systems
New digital display shows kilowatts (kW) when inverting and AMPS (A) when charging
Better thermal performance allows full output power to 50° C (122° F) without de-rating
High surge capacity starts more difficult loads and handles overload conditions reliably
Simplified controls with a snap-on cover that protects settings from being accidentally changed.
About product details:
Applied in the field of industrial process controls, battery charging requirements, personal computers, telecommunications, graphics displays, plating and gold recovery industries and wherever required in the commercial, telecoms, mining or industrial markets. Commercial Solar, Recreational Vehicles, Mobile Office, Industrial Wind, Boats, Truck, & RV Residential Solar, Emergency Vehicles, Residential Wind, Fleet & Utility Vehicles, Camping & Outdoors, Renewable Newsletter, Soft start capability for starting heavy loads
New power factor corrected (PFC) charging
Available in 1000 and 3000 watt models Utility grade, sine wave power
Durable construction for long life under extreme environmental conditions
70 AMP automatic three-stage battery charger (bulk, absorption, and float)
Battery equalization with remote temperature sensor for increased performance
Low idle current (less than 1 watt) conserves energy when no loads are present
Built-in starting control circuits for two- and three-wire generator starting systems
New digital display shows kilowatts (kW) when inverting and AMPS (A) when charging
Better thermal performance allows full output power to 50° C (122° F) without de-rating
High surge capacity starts more difficult loads and handles overload conditions reliably
Simplified controls with a snap-on cover that protects settings from being accidentally changed.
About product details:
MODEL | PV30-1KW MPK | PV30-1.5KW MPK | PV30-2KW MPK | PV30-3KW MPK | PV30-4KW MPK | PV30-5KW MPK | PV30-6KW MPK | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Battery System Voltage | 12VDC | 24VDC | 12VDC | 24VDC | 12VDC | 24VDC | 12VDC | 24VDC | 24VDC/48VDC | 24VDC/48VDC | 24VDC/48VDC | |||||
INVERTER OUTPUT | ||||||||||||||||
Rated Power | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | |||||||||
Surge Rating (20ms) | 3KW | 4.5KW | 6KW | 9KW | 12KW | 15KW | 18KW | |||||||||
Capable Of Starting Electric Motor | 1HP | 1HP | 1HP | 2HP | 2HP | 3HP | 3HP | |||||||||
Waveform | Pure sine wave/ same as input (bypass mode) | Pure sine wave/ same as input (bypass mode) | ||||||||||||||
Nominal Output Voltage RMS | 100V/110V/120VAC 220V/230V/240VAC(+/-10% RMS) | 100V/110V/120VAC 220V/230V/240VAC | 220V/230V/240VAC | |||||||||||||
Output Frequency | 50Hz/60Hz +/-0.3 Hz | 50Hz/60Hz +/-0.3 Hz | ||||||||||||||
Inverter Efficiency(Peak) | >88% | >88% | ||||||||||||||
Line Mode Efficiency | >95% | >95% | ||||||||||||||
Power Factor | 1.0 | 1.0 | ||||||||||||||
Typical Transfer Time | 10ms(max) | 10ms(max) | ||||||||||||||
AC INPUT | ||||||||||||||||
Voltage | 230VAC | 230VAC | ||||||||||||||
Selectable Voltage Range | 96~132VAC 155~280VAC(For Personal Computers) | 96~132VAC/155~280VAC(For Personal Computers) | ||||||||||||||
Frequency Range | 50Hz/60Hz (Auto sensing) 40-80Hz | 50HZ/60HZ (Auto sensing) 40-80Hz | ||||||||||||||
BATTERY | ||||||||||||||||
Minimum Start Voltage | 10.0VDC /10.5VDC for12VDC mode (*2 for 24VDC, ) | 20.0VDC~21.0VDC /40.0VDC~42.0VDC | ||||||||||||||
Low Battery Alarm | 10.5VDC +/-0.3V for12VDC mode (*2 for 24VDC, ) | 21.0VDC+/-0.6V /42.0VDC+/-1.2V | ||||||||||||||
Low Battery Cutoff | 10.0VDC +/-0.3V for12VDC mode (*2 for 24VDC, ) | 20.0VDC+/-0.6V /40.0VDC+/-1.2V | ||||||||||||||
High Voltage Alarm | 16.0VDC +/-0.3V for12VDC mode (*2 for 24VDC, ) | 32.0VDC+/-0.6V /64.0VDC+/-1.2V | ||||||||||||||
High Battery Voltage Recover | 15.5VDC +/-0.3V for12VDC mode (*2 for 24VDC, ) | 31.0VDC+/-0.6V / 62.0VDC+/-1.2V | ||||||||||||||
Idle Consumption-Search Mode | <25W when power saver on | <50W when power saver on | ||||||||||||||
AC CHARGER | ||||||||||||||||
Output Voltage | Depends on battery type | Depends on battery type | ||||||||||||||
Charger AC Input Breaker Rating | 10A | 30A | 30A | 30A | 40A | |||||||||||
Overcharge Protection S.D. | 15.7VDC for 12VDC mode (*2 for 24VDC, ) | 31.4VDC/62.8VDC | ||||||||||||||
Maximum Charge Current | 35A | 20A | 45A | 25A | 65A | 35A | 75A | 45A | 65A | 35A | 70A | 40A | 75A | 50A | ||
BYPASS & PROTECTION | ||||||||||||||||
Input Voltage Waveform | Sine wave (grid or generator) | Sine wave (grid or generator) | ||||||||||||||
Nominal Input Frequency | 50Hz or 60Hz | 50Hz or 60Hz | ||||||||||||||
Overload Protection (SMPS Load) | Circuit breaker | Circuit breaker | ||||||||||||||
Output Short Circuit Protection | Circuit breaker | Circuit breaker | ||||||||||||||
Bypass Breaker Rating | 10A | 15A | 30A | 30A | 40A | |||||||||||
Max Bypass Current | 30Amp | 40Amp | ||||||||||||||
SOLAR CHARGER | ||||||||||||||||
Maximum PV Array Power | 600W | 1200W | 600W | 1200W | 600W | 1200W | 600W | 1200W | 1600W | 3200W | 1600W | 3200W | 1600W | 3200W | ||
Maximum PV Charge Current | 40A | 60A | ||||||||||||||
DC Voltage | 12V/24V atuo work | 24V/48V atuo work | ||||||||||||||
MPPT Range @ Operating Voltage | 16~100VDC@12V/32~145VDC@24V | 32~145VDC @ 24V / 64~145VDC @ 48V | ||||||||||||||
Maximum PV Array Open Circuit Voltage | 100VDC/145VDC | 145VDC | ||||||||||||||
Maximum Efficiency | >90% | >98% | ||||||||||||||
Standby Power Consumption | <2W | <2W | ||||||||||||||
MECHANICAL SPECIFICATIONS | ||||||||||||||||
Mounting | Wall mount | Wall mount | ||||||||||||||
Dimensions (W*H*D) | 423*247*197mm | 597x247x197mm | ||||||||||||||
Net Weight (Solar CHG) kg | 18.5 | 18.4 | 19.5 | 19.4 | 23.5 | 32.2 | 28.7 | 27 | 41.3 | 39.4 | 50.4 | 48.8 | 51.8 | 49.2 | ||
Shipping Dimensions(W*H*D) | 570*355*300mm | 743*372*312mm | ||||||||||||||
Shipping Weight (Solar CHG) kg | 21.5 | 21.4 | 22.4 | 22.5 | 25.8 | 25.6 | 31.2 | 29.6 | 44.7 | 42.8 | 54 | 52.4 | 55.7 | 53.1 | ||
OTHER | ||||||||||||||||
Operation Temperature Range | 0°C to 40°C | |||||||||||||||
Storage Temperature | -15°C to 60°C | |||||||||||||||
Audible Noise | 60dB MAX | |||||||||||||||
Display | LED+LCD | |||||||||||||||
Loading(20GP/40GP/40HQ) | 460pcs / 920pcs / 1060pcs | 320pcs / 640pcs / 750pcs |