120W LED power supply 12V 10A LED driver waterproof power supply
Models
Lpv-120-12.120W 12V 10A
Lpv-120-25, 120W 24V 5A
Lpv-120-36, 120W 36V 3.3A
Lpv-120-48, 120W 48V 2.5A
These power supply have waterproof funtion.
High quality
INPUT DETALIS
110V/220V
Protections: Short circuit/Over load
100% full load burn-in
Lost cost
High reliability
Waterproof and moisture proof
Convenient wiring
Models
Lpv-120-12.120W 12V 10A
Lpv-120-25, 120W 24V 5A
Lpv-120-36, 120W 36V 3.3A
Lpv-120-48, 120W 48V 2.5A
These power supply have waterproof funtion.
High quality
INPUT DETALIS
110V/220V
Protections: Short circuit/Over load
100% full load burn-in
Lost cost
High reliability
Waterproof and moisture proof
Convenient wiring
Model | LPV-120-12 | LPV-120-24 | LPV-120-36 | LPV-120-48 | |
output | DC voltage | 12V | 24V | 36V | 48V |
Voltage tolerance | ±1% | ±1% | ±1% | ±1% | |
Rated current | 10A | 5A | 3.3A | 2.5A | |
Current range | 0~10A | 0~5A | 0~3.3A | 0~2.5A | |
Rated power | 120W | 120W | 118.8W | 120W | |
Ripple&noise | 100mvp-p | 150mvp-p | 150mvp-p | 180mvp-p | |
input | Voltage range | 90~137VAC or 180~264VAC,255~373VDC | |||
Frequency | 47~63HZ | ||||
AC current | 1.2A/230VAC | ||||
Efficiency | 82% | 84% | 84% | 85% | |
Inrush current | Cold start current 40A/230VAC | ||||
Leakage current | <2.5mA/240VAC | ||||
protection | Over load | Rated output power 105%~135%start over load protection | |||
Protection type:hiccup mode,auto-recovery after fault condition is removed | |||||
Over voltage | 15.6~17.8V | 30.6~33.2V | 42.6~44.2V | 54.8~56.6V | |
Protection type:hiccup mode,auto-recovery after fault condition is removed | |||||
Over temperature | Shell temp≥85ºC,start over temperature protection | ||||
Protection mode:cutoff output,auto-recovery after temperature become normal | |||||
environment | Working temp,humidity | -10ºC~+60ºC,20%~90%RH | |||
Storage temp.humidity | -20ºC~+85ºC,10%~95%RH non condensing | ||||
Withstand vibration | 10~500Hz,2G 10min/1cycle,period for 60minutes,each axes | ||||
SAFETY&EMC | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||
Isolated resistance | I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC | ||||
Safety standard | Design Refer To UL1012,IP67 protect level | ||||
EMC standard | EN55022,CLASSA | ||||
Others | Dimension | 215*69*43mm (L*W*H) | |||
Weight/packing | 1.1kg/20pcs/23kg/0.03 m³/1.07CUFT | ||||
Note | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |