Basic Info.
Model NO.
LRS-75
Input Voltage
110-220V
Connection Mode
Series Switching Power Supply
Starting Mode
Self-excited Switching Power Supply
Voltage Regulating Mode
Frequency Modulation Type
Power Supplying System
Terminal Power Distribution Equipment
Energy Transmission
One-way Transmission
Modulation System
PWM
Certification
CE, RoHS
Brand
Leyu
Transport Package
45PCS/Carton
Specification
99*82*30mm
Trademark
Leyu
Origin
China
Production Capacity
50000/PCS/Month
Packaging & Delivery
Package Size
10.00cm * 8.50cm * 3.00cm
Package Gross Weight
0.300kg
Product Description
SPECIFICATION | ||||||
OUTPUT | ||||||
Model | LRS-75-5 | LRS-75-12 | LRS-75-15 | LRS-75-24 | LRS-75-36 | LRS-75-48 |
DC Voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Rated Current | 14A | 6A | 5A | 3.2A | 2.1A | 1.6A |
Current Range | 0~14A | 0~6A | 0~5A | 0~3.2A | 0~2.1A | 0~1.6A |
Rated Power | 70W | 72W | 75W | 76.8W | 75.6W | 76.8W |
Ripple & Noise | 100mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p |
Voltage Adj. Range | 4.5 ~ 5.5V | 10.2~ 13.8V | 13.5~18V | 21.6~28.8V | 32.4~39.6V | 43.2~52.8V |
Voltage Tolerance | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Line Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load Regulation | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Setup, Rise Time | 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load | |||||
Hold Up Time | 60ms/230VAC 12ms/115VAC at full load | |||||
Voltage Range | 85 ~ 264VAC 120 ~ 373VDC | |||||
Frequency Range | 47 ~ 63Hz | |||||
Efficiency | 86.5% | 89% | 89% | 90% | 91.5% | 91.5% |
AC Current | 1.4A/115VAC 0.85A/230VAC | |||||
Inrush Current | Cold start 50A/230VAC | |||||
Leakage Current | <0.75mA / 240VAC | |||||
Over Load | 110 ~ 150% rated output power | |||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||
Over Voltage | 5.75~6.75V | 13.8 ~ 16.2V | 18.75~21.75V | 28.8 ~ 33.6V | 41.4~48.6V | 55.2~ 64.8V |
Protection type: shut down o/p voltage, re-power on to recover | ||||||
Working Temp. | -30 ~ +70ºC (Refer to "derating curve") | |||||
Working Humidity | 20 ~ 90% RH non-condensing | |||||
Storage Temp., Humidity | -40 ~ +85ºC, 10 ~ 95% RH | |||||
Temp. Coefficient | ±0.03%/ºC (0 ~ 50ºC) | |||||
Vibration | 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes | |||||
Safety Standards | UL60950-1, TUV EN60950-1, EN60335-1/-2-16, CCC GB4943 approved | |||||
Withstand Voltage | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC | |||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC / 70% RH | |||||
EMC Emission | Compliance to EN55022(CISPR22), GB9254 CLASS B, EN55014 EN 61000-3-2,-3 | |||||
EMC Immunity | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2), heavy industry level, criteria A | |||||
Dimension | 99*82*30mm (L*W*H) | |||||
Weight | 0.3Kg | |||||
Packing | 45pcs/carton/14.5kg/0.77CUFT | |||||
NOTE | ||||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time. |